How to calculate floor heating pipes
The floor heating pipe is the core component of the floor heating system, and its calculation method directly affects the heating effect and energy consumption of the floor heating. This article will introduce the calculation method of floor heating pipes in detail and provide structured data to help readers better understand and apply it.
1. Basic principles of floor heating pipe calculations

The calculation of floor heating pipes mainly involves factors such as pipe diameter, pipe spacing, pipe length and heat load. The following are the basic steps for calculating floor heating pipes:
1.Determine heat load: Calculate the required heat load (unit: W/m²) based on the room area, insulation performance and local climate conditions.
2.Select pipe diameter: Common floor heating pipe diameters are 16mm, 20mm and 25mm. The selection of pipe diameter needs to be determined based on the heat load and flow rate.
3.Calculate tube spacing: The distance between pipes is usually 150mm-300mm. The specific value needs to be adjusted according to the heat load and pipe diameter.
4.Calculate pipe length: Calculate the required length of floor heating pipes based on the room area and pipe spacing.
2. Specific methods for calculating floor heating pipes
The following are specific formulas and examples for floor heating pipe calculations:
| Calculation project | formula | Example |
|---|---|---|
| heat load | Heat load = room area × unit heat load | 20m² × 100W/m² = 2000W |
| manager | Pipe length = room area / pipe spacing × 1.1 (correction factor) | 20m² / 0.2m × 1.1 = 110m |
| flow rate | Flow rate = heat load / (specific heat capacity of water × temperature difference × pipe cross-sectional area) | 2000W / (4186J/kg·℃ × 10℃ × 0.0002m²) ≈ 0.24m/s |
3. Things to note when calculating floor heating pipes
1.Adjustment of tube spacing: For areas with large heat loads (such as north-facing rooms), the tube spacing can be appropriately reduced; conversely, the tube spacing can be increased.
2.Pipe diameter selection: If the pipe diameter is too small, the flow rate will be too fast and the energy consumption of the pump will be increased; if the pipe diameter is too large, the material cost will increase.
3.Application of correction factors: When calculating the pipe length, the bends and connections of the pipe need to be considered, usually multiplied by a correction factor of 1.1-1.2.
4. Example analysis of floor heating pipe calculation
The following is the calculation process of a practical case:
| Project | numerical value |
|---|---|
| Room area | 30m² |
| Unit heat load | 120W/m² |
| Tube spacing | 200mm |
| Pipe diameter | 20mm |
| heat load | 3600W |
| manager | 165m |
5. Summary
The calculation of floor heating pipes is a systematic project that requires comprehensive consideration of factors such as heat load, pipe diameter, pipe spacing, and pipe length. Through scientific calculations, the efficient operation and energy-saving effect of the floor heating system can be ensured. We hope that the structured data and calculation methods provided in this article can provide readers with a practical reference.